Honeywell XNX XNX-AMSV-FHCB1 – MPD catalytic 0–100 %LEL, mV, ATEX, 316SS, M25
XNX-AMSV-FHCB1 is a factory-configured Honeywell XNX gas detector: mV personality, MPD catalytic bead 0–100 %LEL, ATEX / IECEx (INMETRO on selected MPD SKUs), 4 × M25, 316 stainless steel, Foundation Fieldbus + 4–20 mA HART, local HART port on the transmitter. Specify it for mixed hydrocarbon LEL points where infrared windows would fog or the stream is not methane/propane-specific.
Same sensor, swap enclosure/approval: aluminium XNX-AMAV-FHCB1, 316SS XNX-AMSV-FHCB1, other approval XNX-UTSV-FHCB1. XNX-AMAV-FHCB1 · XNX-AMSV-FHCB1 · XNX-UTSV-FHCB1

Part-number decode
| Segment | Meaning | This SKU |
|---|---|---|
| XNX | Honeywell XNX universal transmitter | XNX |
| A / U | Approval A=ATEX/IECEx; U=UL/cUL | A |
| M / T | Entry M=M25; T=3/4" NPT | M |
| A / S | Enclosure A=aluminium; S=316SS | S |
| V / I / E | Personality V=mV(MPD); I=IR Optima/Excel; E=EC | V |
| N / R / M / F | Option N=HART only; R=relays; M=Modbus; F=FFB | F |
| N / H | Local HART port N=no; H=yes | H |
| CB1 | MPD catalytic 0–100 %LEL | CB1 |
Same sensor, swap enclosure/approval: aluminium XNX-AMAV-FHCB1, 316SS XNX-AMSV-FHCB1, other approval XNX-UTSV-FHCB1.
Technical specifications
| Category | Transmitter Configured |
|---|---|
| Personality | mV personality (MPD catalytic / MPD IR) |
| Sensor / range | MPD catalytic 0–100 %LEL |
| Target | LEL / flammable gas (catalytic) |
| Principle | MPD catalytic bead |
| Output | Foundation Fieldbus + 4–20 mA HART |
| Local HART | local HART port on the transmitter |
| Supply | 16–32 VDC (24 VDC nominal) |
| Enclosure | 316 stainless steel |
| Entries | 4 × M25 |
| Display | Backlit LCD, magnetic-wand menus |
| Ingress | IP66 |
| Approvals | ATEX / IECEx (INMETRO on selected MPD SKUs) |
| Temperature | −40~+65 ℃ |
| Mass | approx. 5.0 kg |
| Mates with | Honeywell MPD catalytic bead or MPD infrared sensors |
Why this personality / sensor
A poison-resistant MPD pellistor sees combustion heat across a wide hydrocarbon mix, including species an IR filter misses. It needs oxygen and hates silicones. Mount above light-gas releases and below heavy vapours; keep silicone sealants off the sinter.
Personality and replaceable parts
XNX-AMSV-FHCB1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD catalytic 0–100 %LEL. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.
Typical applications
Pump rooms, filling gantries and compressor packages still standardise on catalytic LEL because the gas slate is mixed. XNX holds 4–20 mA HART into the ESD matrix; magnetic non-intrusive calibration keeps the flameproof lid closed.
Selection contrast
| P/N | Gas | Range | Option | Body |
|---|---|---|---|---|
| XNX-AMAV-FHCB1 | LEL | 0–100 %LEL | FFB | Aluminium |
| XNX-UTSV-FHCB1 | LEL | 0–100 %LEL | FFB | 316SS |
| XNX-AMSV-FHIV1 | CH₄ | 0–100 %LEL | FFB | 316SS |
| XNX-AMSV-FHIF1 | C₃H₈ | 0–100 %LEL | FFB | 316SS |
| XNX-AMSV-FHIC1 | CO₂ | 0–5 %v/v | FFB | 316SS |
| XNX-AMSV-FHNNN | body | — | FFB | 316SS |
| XNX-AMSV-NHCB1 | LEL | 0–100 %LEL | HART | 316SS |
Installation and wiring
Wall-mount XNX-AMSV-FHCB1 (316 stainless steel, approx. 5.0 kg) on a rigid stand sized for that mass. This SKU uses 4 × M25 entries—glands must match; do not retap XNX-AMSV-FHCB1. Land XNX-AMSV-FHCB1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-AMSV-FHCB1 lid stay non-intrusive. Keep silicones off the XNX-AMSV-FHCB1 pellistor; light hydrocarbons high, heavy vapours low.
FAQ
- Will silicone vapours kill the XNX-AMSV-FHCB1 pellistor?
- Yes. Silicones and chlorinated solvents poison the MPD catalytic bead on XNX-AMSV-FHCB1. Specify IV1/IF1 infrared if those contaminants are routine.
- What bump-test gas should I use on XNX-AMSV-FHCB1?
- Use the target hydrocarbon at 50 %LEL. Methane-only test gas will under-state response if the process is petrol vapour.
- Why is XNX-AMSV-FHCB1 316SS instead of aluminium?
- XNX-AMSV-FHCB1 is the marine/sour-service body (~5 kg). Inland dry rooms can take aluminium sibling XNX-AMAV-FHCB1 and save mass on the bracket.
- Can I convert XNX-AMSV-FHCB1 from ATEX M25 to NPT in the field?
- No. XNX-AMSV-FHCB1 flameproof entries are machined M25. North-American NPT is UL sibling XNX-UTSV-FHCB1, not an adaptor on this ATEX body.
- Is XNX-AMSV-FHCB1 the same as Modbus?
- No. XNX-AMSV-FHCB1 is Foundation Fieldbus. Modbus RTU is sibling XNX-AMSV-MHCB1. Both still carry 4–20 mA HART on XNX.
Documents
Honeywell XNX datasheet / manual · On-site XNX selection matrix
Availability and enquiry
Stock is lot-based. If this box is out, jump to 316SS XNX-AMSV-FHCB1 or UL XNX-UTSV-FHCB1 rather than a dead SKU.