Honeywell XNX XNX-UTAV-MNIC1 – MPD IR carbon dioxide 0–5 %v/v, mV, UL, Aluminium, 3/4" NPT

XNX-UTAV-MNIC1 is a factory-configured Honeywell XNX with MPD infrared carbon dioxide 0–5 %v/v, mV personality, UL / cUL, 4 × 3/4" NPT, LM25 aluminium (painted), Modbus RTU + 4–20 mA HART, no local HART port. Use it on beverage carbonation, inerting cabinets and fermenter headspace—not as a toxic ppm cell.

Same sensor, swap enclosure/approval: aluminium XNX-UTAV-MNIC1, 316SS XNX-UTSV-MNIC1, other approval XNX-AMAV-MNIC1. XNX-UTAV-MNIC1 · XNX-UTSV-MNIC1 · XNX-AMAV-MNIC1

XNX-UTAV-MNIC1 Honeywell XNX carbon dioxide Aluminium 3/4" NPT

Part-number decode

SegmentMeaningThis SKU
XNXHoneywell XNX universal transmitterXNX
A / UApproval A=ATEX/IECEx; U=UL/cULU
M / TEntry M=M25; T=3/4" NPTT
A / SEnclosure A=aluminium; S=316SSA
V / I / EPersonality V=mV(MPD); I=IR Optima/Excel; E=ECV
N / R / M / FOption N=HART only; R=relays; M=Modbus; F=FFBM
N / HLocal HART port N=no; H=yesN
IC1MPD IR carbon dioxide 0–5 %v/vIC1

Same sensor, swap enclosure/approval: aluminium XNX-UTAV-MNIC1, 316SS XNX-UTSV-MNIC1, other approval XNX-AMAV-MNIC1.

Technical specifications

CategoryTransmitter Configured
PersonalitymV personality (MPD catalytic / MPD IR)
Sensor / rangeMPD IR carbon dioxide 0–5 %v/v
TargetCO₂ / carbon dioxide
PrincipleMPD infrared (CO₂)
OutputModbus RTU + 4–20 mA HART
Local HARTno local HART port
Supply16–32 VDC (24 VDC nominal)
EnclosureLM25 aluminium (painted)
Entries4 × 3/4" NPT
DisplayBacklit LCD, magnetic-wand menus
IngressIP66
ApprovalsUL / cUL
Temperature−40~+65 ℃
Massapprox. 2.8 kg
Mates withHoneywell MPD catalytic bead or MPD infrared sensors

Why this personality / sensor

CO₂ is heavier than air and fills cellars from the floor up. Percent-level CO₂ is an IR measurement; an electrochemical toxic cell cannot span 5 %vol. Mount 300 mm above the lowest floor and keep the optical path off wet drains.

Personality and replaceable parts

XNX-UTAV-MNIC1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD IR carbon dioxide 0–5 %v/v. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.

Typical applications

Soft-drink carbonation, brewery cellars and CO₂-inerted cabinets need a 5 %vol trip before asphyxiation. XNX provides the hard-wired extract start; a portable wand is only a leak survey tool.

Selection contrast

P/NGasRangeOptionBody
XNX-UTSV-MNIC1CO₂0–5 %v/vModbus316SS
XNX-AMAV-MNIC1CO₂0–5 %v/vModbusAluminium
XNX-UTAV-MNCB1LEL0–100 %LELModbusAluminium
XNX-UTAV-MNIV1CH₄0–100 %LELModbusAluminium
XNX-UTAV-MNIF1C₃H₈0–100 %LELModbusAluminium
XNX-UTAV-MNNNNbodyModbusAluminium
XNX-UTAV-NNIC1CO₂0–5 %v/vHARTAluminium

XNX family matrix

Installation and wiring

Wall-mount XNX-UTAV-MNIC1 (LM25 aluminium (painted), approx. 2.8 kg) on a rigid stand sized for that mass. This SKU uses 4 × 3/4" NPT entries—glands must match; do not retap XNX-UTAV-MNIC1. Land XNX-UTAV-MNIC1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-UTAV-MNIC1 lid stay non-intrusive. XNX-UTAV-MNIC1 5 %v/v CO₂ hugs the cellar floor.

FAQ

Is XNX-UTAV-MNIC1 a toxic ppm CO₂ detector?
No. XNX-UTAV-MNIC1 is 0–5 %v/v IR for asphyxiation / inerting. ppm indoor-air CO₂ is a different instrument class.
Should I mount XNX-UTAV-MNIC1 high or low?
Low. CO₂ is heavier than air. Keep XNX-UTAV-MNIC1 about 300 mm above the lowest floor, not at the roof ridge.
When should I swap XNX-UTAV-MNIC1 aluminium for 316SS?
Use XNX-UTAV-MNIC1 (aluminium, ~2.8 kg) in inland, painted plant. Coastal, splash and sour-water decks should move to stainless sibling XNX-UTSV-MNIC1.
Why is XNX-UTAV-MNIC1 NPT instead of M25?
XNX-UTAV-MNIC1 is the UL/cUL body and ships 3/4" NPT. Do not tap M25 on this lid—order ATEX sibling XNX-AMAV-MNIC1 if metric glands are mandatory.
Can I retrofit Foundation Fieldbus on XNX-UTAV-MNIC1 after it ships?
No. XNX-UTAV-MNIC1 is the Modbus RTU option board. FFB is a different sales option (XNX-UTAV-FNIC1), not a jumper on this lid.

Documents

Honeywell XNX datasheet / manual · On-site XNX selection matrix

Availability and enquiry

Stock is lot-based. If this box is out, jump to 316SS XNX-UTSV-MNIC1 or UL XNX-UTAV-MNIC1 rather than a dead SKU.