SENKO SI-H100 extractive wall mount, sample up to 30 m, smart cartridge, Ethernet PoE, optional pyrolyzer (e.g. NF₃).

| Item | Spesifikasi |
|---|---|
| Gas sasaran & julat | Mengikut kepala; sedutan |
| Jenis | SI-H100 sedutan |
| Output & penggera | 4–20 mA, relay/RS-485 pilihan |
| Perlindungan & Ex | IP65/66; Ex d atau IS |
| Suhu operasi | −20 hingga +55 °C |
| Sijil / penerimaan | SENKO Korea. IECEx pada nameplate. Imbasan GB bukan setara. |
Dari data SENKO. Nameplate menang.
Pump ~2 years. 3 relays, 4–20 mA, Modbus/TCP, web firmware. ppb-capable.
| Model | SI-H100 |
| Principle | Smart sensor cartridge (+ optional pyrolyzer) |
| Method | Extractive pump |
| IP | wall enclosure |
| Certification | Ethernet/industrial (catalog) |
Fabs, WWTPs and pipe galleries where the point is remote or needs pyrolysis: extractive sampling up to ~30 m with Modbus/TCP and relay outputs.
| Model | Gas sasaran | When to pick it |
|---|---|---|
| SI-301 | O₂/toxic/LEL by cartridge | Ex d extractive for fabs / WWTP |
| SI-310 | C₄F₆ / C₅F₈ / CH₂F₂ / CH₃F via pyrolysis | Built-in pyrolyzer for fab specialty gases |