Honeywell XNX XNX-AMAV-NHCB1 – MPD catalytic 0–100 %LEL, mV, ATEX, Aluminium, M25

XNX-AMAV-NHCB1 is a factory-configured Honeywell XNX gas detector: mV personality, MPD catalytic bead 0–100 %LEL, ATEX / IECEx (INMETRO on selected MPD SKUs), 4 × M25, LM25 aluminium (painted), 4–20 mA HART only (no option board), local HART port on the transmitter. Specify it for mixed hydrocarbon LEL points where infrared windows would fog or the stream is not methane/propane-specific.

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-NHCB1, 316SS XNX-AMSV-NHCB1, other approval XNX-UTAV-NHCB1. XNX-AMAV-NHCB1 · XNX-AMSV-NHCB1 · XNX-UTAV-NHCB1

XNX-AMAV-NHCB1 Honeywell XNX flammable gas (catalytic) Aluminium M25

Part-number decode

SegmentMeaningThis SKU
XNXHoneywell XNX universal transmitterXNX
A / UApproval A=ATEX/IECEx; U=UL/cULA
M / TEntry M=M25; T=3/4" NPTM
A / SEnclosure A=aluminium; S=316SSA
V / I / EPersonality V=mV(MPD); I=IR Optima/Excel; E=ECV
N / R / M / FOption N=HART only; R=relays; M=Modbus; F=FFBN
N / HLocal HART port N=no; H=yesH
CB1MPD catalytic 0–100 %LELCB1

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-NHCB1, 316SS XNX-AMSV-NHCB1, other approval XNX-UTAV-NHCB1.

Technical specifications

CategoryTransmitter Configured
PersonalitymV personality (MPD catalytic / MPD IR)
Sensor / rangeMPD catalytic 0–100 %LEL
TargetLEL / flammable gas (catalytic)
PrincipleMPD catalytic bead
Output4–20 mA HART only (no option board)
Local HARTlocal HART port on the transmitter
Supply16–32 VDC (24 VDC nominal)
EnclosureLM25 aluminium (painted)
Entries4 × M25
DisplayBacklit LCD, magnetic-wand menus
IngressIP66
ApprovalsATEX / IECEx (INMETRO on selected MPD SKUs)
Temperature−40~+65 ℃
Massapprox. 2.8 kg
Mates withHoneywell MPD catalytic bead or MPD infrared sensors

Why this personality / sensor

A poison-resistant MPD pellistor sees combustion heat across a wide hydrocarbon mix, including species an IR filter misses. It needs oxygen and hates silicones. Mount above light-gas releases and below heavy vapours; keep silicone sealants off the sinter.

Personality and replaceable parts

XNX-AMAV-NHCB1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD catalytic 0–100 %LEL. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.

Typical applications

Pump rooms, filling gantries and compressor packages still standardise on catalytic LEL because the gas slate is mixed. XNX holds 4–20 mA HART into the ESD matrix; magnetic non-intrusive calibration keeps the flameproof lid closed.

Selection contrast

P/NGasRangeOptionBody
XNX-AMSV-NHCB1LEL0–100 %LELHART316SS
XNX-UTAV-NHCB1LEL0–100 %LELHARTAluminium
XNX-AMAV-NHIV1CH₄0–100 %LELHARTAluminium
XNX-AMAV-NHIF1C₃H₈0–100 %LELHARTAluminium
XNX-AMAV-NHIC1CO₂0–5 %v/vHARTAluminium
XNX-AMAV-NHNNNbodyHARTAluminium
XNX-AMAV-RHCB1LEL0–100 %LELRelaysAluminium

XNX family matrix

Installation and wiring

Wall-mount XNX-AMAV-NHCB1 (LM25 aluminium (painted), approx. 2.8 kg) on a rigid stand sized for that mass. This SKU uses 4 × M25 entries—glands must match; do not retap XNX-AMAV-NHCB1. Land XNX-AMAV-NHCB1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-AMAV-NHCB1 lid stay non-intrusive. Keep silicones off the XNX-AMAV-NHCB1 pellistor; light hydrocarbons high, heavy vapours low.

FAQ

Will silicone vapours kill the XNX-AMAV-NHCB1 pellistor?
Yes. Silicones and chlorinated solvents poison the MPD catalytic bead on XNX-AMAV-NHCB1. Specify IV1/IF1 infrared if those contaminants are routine.
What bump-test gas should I use on XNX-AMAV-NHCB1?
Use the target hydrocarbon at 50 %LEL. Methane-only test gas will under-state response if the process is petrol vapour.
When should I swap XNX-AMAV-NHCB1 aluminium for 316SS?
Use XNX-AMAV-NHCB1 (aluminium, ~2.8 kg) in inland, painted plant. Coastal, splash and sour-water decks should move to stainless sibling XNX-AMSV-NHCB1.
Can I convert XNX-AMAV-NHCB1 from ATEX M25 to NPT in the field?
No. XNX-AMAV-NHCB1 flameproof entries are machined M25. North-American NPT is UL sibling XNX-UTAV-NHCB1, not an adaptor on this ATEX body.
Does XNX-AMAV-NHCB1 include alarm relays?
No. XNX-AMAV-NHCB1 is 4–20 mA HART only. Local trip contacts need option-R sibling XNX-AMAV-RHCB1; plant-bus needs Modbus XNX-AMAV-MHCB1 or Foundation Fieldbus XNX-AMAV-FHCB1.

Documents

Honeywell XNX datasheet / manual · On-site XNX selection matrix

Availability and enquiry

Stock is lot-based. If this box is out, jump to 316SS XNX-AMSV-NHCB1 or UL XNX-UTAV-NHCB1 rather than a dead SKU.

WhatsAppTop