Honeywell XNX XNX-AMSV-NHIC1 – MPD IR carbon dioxide 0–5 %v/v, mV, ATEX, 316SS, M25

XNX-AMSV-NHIC1 is a factory-configured Honeywell XNX with MPD infrared carbon dioxide 0–5 %v/v, mV personality, ATEX / IECEx (INMETRO on selected MPD SKUs), 4 × M25, 316 stainless steel, 4–20 mA HART only (no option board), local HART port on the transmitter. Use it on beverage carbonation, inerting cabinets and fermenter headspace—not as a toxic ppm cell.

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-NHIC1, 316SS XNX-AMSV-NHIC1, other approval XNX-UTSV-NHIC1. XNX-AMAV-NHIC1 · XNX-AMSV-NHIC1 · XNX-UTSV-NHIC1

XNX-AMSV-NHIC1 Honeywell XNX carbon dioxide 316SS M25

Part-number decode

SegmentMeaningThis SKU
XNXHoneywell XNX universal transmitterXNX
A / UApproval A=ATEX/IECEx; U=UL/cULA
M / TEntry M=M25; T=3/4" NPTM
A / SEnclosure A=aluminium; S=316SSS
V / I / EPersonality V=mV(MPD); I=IR Optima/Excel; E=ECV
N / R / M / FOption N=HART only; R=relays; M=Modbus; F=FFBN
N / HLocal HART port N=no; H=yesH
IC1MPD IR carbon dioxide 0–5 %v/vIC1

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-NHIC1, 316SS XNX-AMSV-NHIC1, other approval XNX-UTSV-NHIC1.

Technical specifications

CategoryTransmitter Configured
PersonalitymV personality (MPD catalytic / MPD IR)
Sensor / rangeMPD IR carbon dioxide 0–5 %v/v
TargetCO₂ / carbon dioxide
PrincipleMPD infrared (CO₂)
Output4–20 mA HART only (no option board)
Local HARTlocal HART port on the transmitter
Supply16–32 VDC (24 VDC nominal)
Enclosure316 stainless steel
Entries4 × M25
DisplayBacklit LCD, magnetic-wand menus
IngressIP66
ApprovalsATEX / IECEx (INMETRO on selected MPD SKUs)
Temperature−40~+65 ℃
Massapprox. 5.0 kg
Mates withHoneywell MPD catalytic bead or MPD infrared sensors

Why this personality / sensor

CO₂ is heavier than air and fills cellars from the floor up. Percent-level CO₂ is an IR measurement; an electrochemical toxic cell cannot span 5 %vol. Mount 300 mm above the lowest floor and keep the optical path off wet drains.

Personality and replaceable parts

XNX-AMSV-NHIC1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD IR carbon dioxide 0–5 %v/v. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.

Typical applications

Soft-drink carbonation, brewery cellars and CO₂-inerted cabinets need a 5 %vol trip before asphyxiation. XNX provides the hard-wired extract start; a portable wand is only a leak survey tool.

Selection contrast

P/NGasRangeOptionBody
XNX-AMAV-NHIC1CO₂0–5 %v/vHARTAluminium
XNX-UTSV-NHIC1CO₂0–5 %v/vHART316SS
XNX-AMSV-NHCB1LEL0–100 %LELHART316SS
XNX-AMSV-NHIV1CH₄0–100 %LELHART316SS
XNX-AMSV-NHIF1C₃H₈0–100 %LELHART316SS
XNX-AMSV-NHNNNbodyHART316SS
XNX-AMSV-RHIC1CO₂0–5 %v/vRelays316SS

XNX family matrix

Installation and wiring

Wall-mount XNX-AMSV-NHIC1 (316 stainless steel, approx. 5.0 kg) on a rigid stand sized for that mass. This SKU uses 4 × M25 entries—glands must match; do not retap XNX-AMSV-NHIC1. Land XNX-AMSV-NHIC1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-AMSV-NHIC1 lid stay non-intrusive. XNX-AMSV-NHIC1 5 %v/v CO₂ hugs the cellar floor.

FAQ

Is XNX-AMSV-NHIC1 a toxic ppm CO₂ detector?
No. XNX-AMSV-NHIC1 is 0–5 %v/v IR for asphyxiation / inerting. ppm indoor-air CO₂ is a different instrument class.
Should I mount XNX-AMSV-NHIC1 high or low?
Low. CO₂ is heavier than air. Keep XNX-AMSV-NHIC1 about 300 mm above the lowest floor, not at the roof ridge.
Why is XNX-AMSV-NHIC1 316SS instead of aluminium?
XNX-AMSV-NHIC1 is the marine/sour-service body (~5 kg). Inland dry rooms can take aluminium sibling XNX-AMAV-NHIC1 and save mass on the bracket.
Can I convert XNX-AMSV-NHIC1 from ATEX M25 to NPT in the field?
No. XNX-AMSV-NHIC1 flameproof entries are machined M25. North-American NPT is UL sibling XNX-UTSV-NHIC1, not an adaptor on this ATEX body.
Does XNX-AMSV-NHIC1 include alarm relays?
No. XNX-AMSV-NHIC1 is 4–20 mA HART only. Local trip contacts need option-R sibling XNX-AMSV-RHIC1; plant-bus needs Modbus XNX-AMSV-MHIC1 or Foundation Fieldbus XNX-AMSV-FHIC1.

Documents

Honeywell XNX datasheet / manual · On-site XNX selection matrix

Availability and enquiry

Stock is lot-based. If this box is out, jump to 316SS XNX-AMSV-NHIC1 or UL XNX-UTSV-NHIC1 rather than a dead SKU.

WhatsAppTop