Honeywell XNX XNX-AMAV-RHIC1 – MPD IR carbon dioxide 0–5 %v/v, mV, ATEX, Aluminium, M25

XNX-AMAV-RHIC1 is a factory-configured Honeywell XNX with MPD infrared carbon dioxide 0–5 %v/v, mV personality, ATEX / IECEx (INMETRO on selected MPD SKUs), 4 × M25, LM25 aluminium (painted), 3 relays + 4–20 mA HART, local HART port on the transmitter. Use it on beverage carbonation, inerting cabinets and fermenter headspace—not as a toxic ppm cell.

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-RHIC1, 316SS XNX-AMSV-RHIC1, other approval XNX-UTAV-RHIC1. XNX-AMAV-RHIC1 · XNX-AMSV-RHIC1 · XNX-UTAV-RHIC1

XNX-AMAV-RHIC1 Honeywell XNX carbon dioxide Aluminium M25

Part-number decode

SegmentMeaningThis SKU
XNXHoneywell XNX universal transmitterXNX
A / UApproval A=ATEX/IECEx; U=UL/cULA
M / TEntry M=M25; T=3/4" NPTM
A / SEnclosure A=aluminium; S=316SSA
V / I / EPersonality V=mV(MPD); I=IR Optima/Excel; E=ECV
N / R / M / FOption N=HART only; R=relays; M=Modbus; F=FFBR
N / HLocal HART port N=no; H=yesH
IC1MPD IR carbon dioxide 0–5 %v/vIC1

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-RHIC1, 316SS XNX-AMSV-RHIC1, other approval XNX-UTAV-RHIC1.

Technical specifications

CategoryTransmitter Configured
PersonalitymV personality (MPD catalytic / MPD IR)
Sensor / rangeMPD IR carbon dioxide 0–5 %v/v
TargetCO₂ / carbon dioxide
PrincipleMPD infrared (CO₂)
Output3 relays + 4–20 mA HART
Local HARTlocal HART port on the transmitter
Supply16–32 VDC (24 VDC nominal)
EnclosureLM25 aluminium (painted)
Entries4 × M25
DisplayBacklit LCD, magnetic-wand menus
IngressIP66
ApprovalsATEX / IECEx (INMETRO on selected MPD SKUs)
Temperature−40~+65 ℃
Massapprox. 2.8 kg
Mates withHoneywell MPD catalytic bead or MPD infrared sensors

Why this personality / sensor

CO₂ is heavier than air and fills cellars from the floor up. Percent-level CO₂ is an IR measurement; an electrochemical toxic cell cannot span 5 %vol. Mount 300 mm above the lowest floor and keep the optical path off wet drains.

Personality and replaceable parts

XNX-AMAV-RHIC1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD IR carbon dioxide 0–5 %v/v. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.

Typical applications

Soft-drink carbonation, brewery cellars and CO₂-inerted cabinets need a 5 %vol trip before asphyxiation. XNX provides the hard-wired extract start; a portable wand is only a leak survey tool.

Selection contrast

P/NGasRangeOptionBody
XNX-AMSV-RHIC1CO₂0–5 %v/vRelays316SS
XNX-UTAV-RHIC1CO₂0–5 %v/vRelaysAluminium
XNX-AMAV-RHCB1LEL0–100 %LELRelaysAluminium
XNX-AMAV-RHIV1CH₄0–100 %LELRelaysAluminium
XNX-AMAV-RHIF1C₃H₈0–100 %LELRelaysAluminium
XNX-AMAV-RHNNNbodyRelaysAluminium
XNX-AMAV-NHIC1CO₂0–5 %v/vHARTAluminium

XNX family matrix

Installation and wiring

Wall-mount XNX-AMAV-RHIC1 (LM25 aluminium (painted), approx. 2.8 kg) on a rigid stand sized for that mass. This SKU uses 4 × M25 entries—glands must match; do not retap XNX-AMAV-RHIC1. Land XNX-AMAV-RHIC1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-AMAV-RHIC1 lid stay non-intrusive. XNX-AMAV-RHIC1 5 %v/v CO₂ hugs the cellar floor.

FAQ

Is XNX-AMAV-RHIC1 a toxic ppm CO₂ detector?
No. XNX-AMAV-RHIC1 is 0–5 %v/v IR for asphyxiation / inerting. ppm indoor-air CO₂ is a different instrument class.
Should I mount XNX-AMAV-RHIC1 high or low?
Low. CO₂ is heavier than air. Keep XNX-AMAV-RHIC1 about 300 mm above the lowest floor, not at the roof ridge.
When should I swap XNX-AMAV-RHIC1 aluminium for 316SS?
Use XNX-AMAV-RHIC1 (aluminium, ~2.8 kg) in inland, painted plant. Coastal, splash and sour-water decks should move to stainless sibling XNX-AMSV-RHIC1.
Can I convert XNX-AMAV-RHIC1 from ATEX M25 to NPT in the field?
No. XNX-AMAV-RHIC1 flameproof entries are machined M25. North-American NPT is UL sibling XNX-UTAV-RHIC1, not an adaptor on this ATEX body.
What do the three relays on XNX-AMAV-RHIC1 do?
XNX-AMAV-RHIC1 adds three configurable relays on top of 4–20 mA HART—typically A1/A2/fault. It is not Modbus; bus siblings are XNX-AMAV-MHIC1 / XNX-AMAV-FHIC1.

Documents

Honeywell XNX datasheet / manual · On-site XNX selection matrix

Availability and enquiry

Stock is lot-based. If this box is out, jump to 316SS XNX-AMSV-RHIC1 or UL XNX-UTAV-RHIC1 rather than a dead SKU.