Honeywell XNX XNX-AMAV-RHIF1 – MPD IR propane 0–100 %LEL, mV, ATEX, Aluminium, M25

XNX-AMAV-RHIF1 is a factory-configured Honeywell XNX with MPD infrared propane 0–100 %LEL, mV personality, ATEX / IECEx (INMETRO on selected MPD SKUs), 4 × M25, LM25 aluminium (painted), 3 relays + 4–20 mA HART, local HART port on the transmitter. Order it for LPG bullets and cylinder halls; methane IR (IV1) will under-read propane.

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-RHIF1, 316SS XNX-AMSV-RHIF1, other approval XNX-UTAV-RHIF1. XNX-AMAV-RHIF1 · XNX-AMSV-RHIF1 · XNX-UTAV-RHIF1

XNX-AMAV-RHIF1 Honeywell XNX propane Aluminium M25

Part-number decode

SegmentMeaningThis SKU
XNXHoneywell XNX universal transmitterXNX
A / UApproval A=ATEX/IECEx; U=UL/cULA
M / TEntry M=M25; T=3/4" NPTM
A / SEnclosure A=aluminium; S=316SSA
V / I / EPersonality V=mV(MPD); I=IR Optima/Excel; E=ECV
N / R / M / FOption N=HART only; R=relays; M=Modbus; F=FFBR
N / HLocal HART port N=no; H=yesH
IF1MPD IR propane 0–100 %LELIF1

Same sensor, swap enclosure/approval: aluminium XNX-AMAV-RHIF1, 316SS XNX-AMSV-RHIF1, other approval XNX-UTAV-RHIF1.

Technical specifications

CategoryTransmitter Configured
PersonalitymV personality (MPD catalytic / MPD IR)
Sensor / rangeMPD IR propane 0–100 %LEL
TargetC₃H₈ / propane
PrincipleMPD infrared (propane)
Output3 relays + 4–20 mA HART
Local HARTlocal HART port on the transmitter
Supply16–32 VDC (24 VDC nominal)
EnclosureLM25 aluminium (painted)
Entries4 × M25
DisplayBacklit LCD, magnetic-wand menus
IngressIP66
ApprovalsATEX / IECEx (INMETRO on selected MPD SKUs)
Temperature−40~+65 ℃
Massapprox. 2.8 kg
Mates withHoneywell MPD catalytic bead or MPD infrared sensors

Why this personality / sensor

Propane is heavier than air and slides into pits. MPD IR tuned for C₃ does not need oxygen and ignores silicone poisons that kill CB1 beads. Mount 200–400 mm above grade at the pit lip, not on the roof.

Personality and replaceable parts

XNX-AMAV-RHIF1 uses the mV personality (MPD catalytic / MPD IR) board and mates with Honeywell MPD catalytic bead or MPD infrared sensors. Factory-fitted with MPD IR propane 0–100 %LEL. Spares live on product-3991. Do not substitute Sensepoint XCD cartridges on XNX.

Typical applications

LPG tank farms, bottle-filling halls and kitchen-gas manifolds need a propane-specific IR trip. XNX hard-wires 4–20 mA HART to tank ESD; a handheld only proves the aisle you walked.

Selection contrast

P/NGasRangeOptionBody
XNX-AMSV-RHIF1C₃H₈0–100 %LELRelays316SS
XNX-UTAV-RHIF1C₃H₈0–100 %LELRelaysAluminium
XNX-AMAV-RHCB1LEL0–100 %LELRelaysAluminium
XNX-AMAV-RHIV1CH₄0–100 %LELRelaysAluminium
XNX-AMAV-RHIC1CO₂0–5 %v/vRelaysAluminium
XNX-AMAV-RHNNNbodyRelaysAluminium
XNX-AMAV-NHIF1C₃H₈0–100 %LELHARTAluminium

XNX family matrix

Installation and wiring

Wall-mount XNX-AMAV-RHIF1 (LM25 aluminium (painted), approx. 2.8 kg) on a rigid stand sized for that mass. This SKU uses 4 × M25 entries—glands must match; do not retap XNX-AMAV-RHIF1. Land XNX-AMAV-RHIF1 4–20 mA HART per the loop drawing; relays/Modbus/FFB exist only on the matching option board. Magnetic-wand menus on the XNX-AMAV-RHIF1 lid stay non-intrusive. XNX-AMAV-RHIF1 propane belongs at the pit lip, not the roof.

FAQ

Can I use methane IR instead of XNX-AMAV-RHIF1 on an LPG skid?
No. Response curves differ. XNX-AMAV-RHIF1 is propane (IF1). IV1 methane IR will under-alarm a propane release.
Does XNX-AMAV-RHIF1 work in oxygen-free LPG vapour space?
Yes. MPD IR on XNX-AMAV-RHIF1 does not combust the sample, so inerted LPG vapour spaces remain measurable.
When should I swap XNX-AMAV-RHIF1 aluminium for 316SS?
Use XNX-AMAV-RHIF1 (aluminium, ~2.8 kg) in inland, painted plant. Coastal, splash and sour-water decks should move to stainless sibling XNX-AMSV-RHIF1.
Can I convert XNX-AMAV-RHIF1 from ATEX M25 to NPT in the field?
No. XNX-AMAV-RHIF1 flameproof entries are machined M25. North-American NPT is UL sibling XNX-UTAV-RHIF1, not an adaptor on this ATEX body.
What do the three relays on XNX-AMAV-RHIF1 do?
XNX-AMAV-RHIF1 adds three configurable relays on top of 4–20 mA HART—typically A1/A2/fault. It is not Modbus; bus siblings are XNX-AMAV-MHIF1 / XNX-AMAV-FHIF1.

Documents

Honeywell XNX datasheet / manual · On-site XNX selection matrix

Availability and enquiry

Stock is lot-based. If this box is out, jump to 316SS XNX-AMSV-RHIF1 or UL XNX-UTAV-RHIF1 rather than a dead SKU.